User guide • Read online or download PDF • DeLonghi PINGUINO PAC T110P User Manual • DeLonghi Conditioners. Manuals Directory ManualsDir.com - online owner manuals library. DeLonghi manuals. PINGUINO PAC T110P. Manual DeLonghi PINGUINO PAC T110P User Manual DeLonghi Conditioners. 20 Most Recent DeLonghi PAC C110 Portable Air Conditioner Questions & Answers. I have a Delonghi portable Split pinguino spazio and I need a operating manual.
Pac160 GB 10:19 Pagina 4 Important Safe-guards When using electrical appliances, basic safety precautions should always be taken, with particular reference to the following: - Read all instructions. To protect against fire, electric shock and personal injury, do not immerse cable, plug or appliance in water or other liquid. Close supervision is necessary when any appliance is used by or near children. Unplug from socket when not in use and before cleaning. Do not operate if the cable, plug or unit itself is damaged or faulty. Return the appliance to the nearest authorised service centre for examination, repair or adjustment. The use of accessories or spare parts other than those recommended by the manufacturer may result in fire, electric shock or personal injury.
Do not use outdoors. Do not use the appliance in ways other than that for which it was intended. Do not place the power cable under strain. Avoid twisting and/or tangling. Ensure that the outlet of the discharge hose is kept free from debris and blockages. Do not obstruct the ventilation holes at the rear of the unit or the front grilles.
The Pinguino should not be installed where there may be combustible gases in the atmosphere. Avoid using Pinguino in oily or sulphurous atmospheres or near sources of heat.
Before moving the air conditioner, empty water from condensation tray (see drainage instructions on page 15). Do not place hot or heavy objects on the unit. Clean air filter every week (see instructions on page 16). To disconnect, turn control to “OFF”, then unplug from wall socket. Important: if an extension is required, use heavy duty cable only (minimum 14 gauge SAVE THESE INSTRUCTIONS. How does your pinguino work During the summer, optimum comfort is achieved with a temperature of between 75-80°F(2427°C) and about 50% relative humidity.
An air conditioner removes moisture and heat from the room where it is located. One advantage of portable air conditioning units over fitted models is that they can be moved from one room to another in the home or even transferred between different buildings. The hot air in your room is passed through a coil cooled by refrigerant gas, losing excess heat and moisture before being discharged again into the room. In Pinguino, a small part of this air is used to cool the refrigerant gas before, hot and moist, being discharged outside. Each Pinguino can also be used as a fan only.
For more details, contact: DE’LONGHI AMERICA INC. Tel: 1-800-322-3848 DE’LONGHI CANADA or visit our Internet site www.delonghi.com. Pinguino is equipped with an adjustable window bracket 18. If you have a sliding window, place the bracket on the window sill, extend the bracket fully within the window frame and lower the window onto the bracket. Insert the nozzle of the exhaust hose into the slot, then connect the hose to the air conditioner (Fig.4).
Thanks to the wing nut, it’s possible to use the window bracket also for sliding windows. Position the hole of the bracket to allow a correct installation of the exhaust hose (see the following instructions). Fit the flange (13) supplied to the hole. Fix the hose (14) in the housing at the rear of the appliance (fig 1). Fit the end of the hose to the flange (15) as shown in fig. MAX 45,3' MAX 115 cm MIN 19,7' MIN 50 cm 9 When the hose (14) is not connected, the hole can be closed off with the flange stopper (13).
When operating the appliance with semi-per-manent installation, it is advisable to leave a door slightly ajar (even only 1cm), to ensure free circulation of air. DEHUMIDIFICATION Position the appliance in the room without inserting the air exhaust hose (14); this ensures that the dehumidified air will be released directly into the atmosphere. The air emitted through the front grill will be cold while the air from the rear will be warm (fig. 10) thus ensuring that the room is dehumidified without variation in temperature.
Pac160 GB 10:19 Pagina 10 Description of the control panel THE DISPLAY A. ON/OFF Button B. Function Button Air-conditioning,dehumidifying, ventilation C. Air-conditioningindicator light D. Dehumidifying indicator light E. Ventilation indicator light F. Increase temperature button / increase operating time button G.
Decrease temperature button / Decrease operating time button H. Display Displays the temperature selected, time programmed I. Timer button L. Timer operation indicator M/N/O/P.
Fan speed indicator Q. Fan speed button ELECTRICAL CONNECTION Before plugging in check that:. the mains supply corresponds to the value shown in the specifications table;. the socket and the mains lead correspond to the power requirements of the appliance;. the socket is suited to the plug, otherwise have the socket replaced;.
the socket is properly grounded. The manufactures cannot be held responsible for any damages due to failure in following normal safety procedures. Replacement of the power cable must be carried out by qualified personnel.
Pac160 GB 10:19 Pagina 11 O p e r a t i o n SWITCHING THE APPLIANCE ON Connect the appliance to the mains supply. On the display two lines will appear indicating Stand-bymode Press the ON/OFF button (A) and then the MODE button until the relevant function indicator appears viz.: Indicator C: air-conditioning Indicator D: dehumidifying Indicator E: ventilation AIR-CONDITIONINGFUNCTION This function is ideal in hot, humid weather conditions when the atmosphere requires to be cooled and dehumidified. To ensure proper function of the appliance, after selecting the airconditioning function, press buttons + (F) or – (G) until the desired temperature appears on the display. The temperatures most suited to the atmosphere in summer vary between (24-27°C) 75°-80°F.We do not advise selection of tem- 77 peratures much lower than those outside.
Select fan speed by pressing the “FAN” button (Q) until the fan speed indicator appears: MAX (P): if you want the maximum power of the air-conditionerto reach the desired temperature as quickly as possible. MIN (O): if you want to reduce the level of noise and still maintain a good level of comfort. SILENT (N):when minimum noise is required, AUTO (M):if you prefer the appliance to select the fan speed for the temperature selected on the display panel. DEHUMIDIFYING FUNCTION This function is ideal for reducing humidity in the atmosphere while avoiding increases or decreases in temperature (in between seasons, damp places, wet spells of weather). When you select the dehumidifying function, the letters “ ” will appear on the display.
The water is collected in the tank at the rear of the appliance. When the tank is full, the appliance will stop working and the display will show the letters “ ” (Full Tank); the tank must then be emptied. When it is re-inserted,the appliance will re-startautomatically. Remove the air exhaust hose (14).
In the air-conditioningfunction, the unit employs an exclusive condensation recycling system to dispose of excess moisture. In normal conditions, condensation is disposed of automatically. When the humidity is particularly high, an excess of condensation may built up in the TANK 9. When this happens, the display will show the letters “ “ (Full Tank); indicating that the TANK should be emptied. Whenever conditions of high humidity make the problem recurrent, you may discharge the excess water directly into a drain, using the rubber tube supplied.
The tube should be inserted into the hole provided, after having removed the rubber stopper. (see figure). Make sure the TANK is put back correctly otherwise the display will continue to show the letters “ ”. Pac160 GB 10:19 Pagina 12 O p e r a t i o n Once the dehumidifying function has been selected, the fan speed cannot be changed. The appliance will automatically select the correct fan mode.
“Silent” speed VENTILATION Adjust the fan speed by pressing the “FAN” (Q) button, as illustra- ted in the air conditioning function. “Min” Bear in mind that the higher the speed, the greater the volume of speed air filtered; by selecting the “Silent” speed, less air is filtered, but the noise level is low. “AUTO” function cannot be selected in this mode.
The display will show the fan speed selected. “Max” speed PROGRAMMING THE TIMER The timer programs the appliance to switch on and switch off. This will save electrical energy by optimizing the operating times. The timer is set using the buttons + (F) or – (G); these increase and decrease by one hour at a time, but if pressed for more than 2 seconds will automatically change the time more quickly, up to a maximum of 24 hours.
How to set the delayed start function. Connect the appliance to the mains supply and press ON/OFF button: next, select the required operating mode (temperature, fan speed etc.).
Press the ON/OFF button again: the appliance will go into stand-bymode. Press the timer button (I): on the display the two central segments will start to flash. Set the number of hours after which the appliance should swit- ch on, by pressing the + or – buttons.
The indicator (L) on the display will continue to flash until the appliance starts operating. The appliance can be programmed for up to 24 hours in advance. How to set the delayed stop function. The appliance can be programmed for delayed stop from any of the operating modes (air-conditioning/dehumidifying/venti- lation. Press the Timer button (I): on the display the two central seg- ments will start to flash.
24. Set the number of hours after which the appliance should swit- ch off by pressing the + or – buttons. The indicator (L) on the display will continue to flash until the appliance switches itself off. It will then go into Stand-bymode. IF THE DISPLAY SHOWS.WHAT SHOULD YOU DO?
H P HIGH PRESSURE Insert and re-insertthe plug. If the problem persists, call the service centre. LOW TEMPERATURE If the machine is operating as an air-conditioneror dehumidifier, this will prevent the formation of ice. The appliance will start up auto- matically once the defrosting process has ended. F F FAN FAILURE If either of these messages appears, call the service centre. P F PROBE FAILURE FULL TANK Empty the tank at the rear of the appliance and reposition correctly.
Before cleaning or maintenance, switch off the appliance by pressing the ON/OFF button (A) and always unplug it from the mains supply. CLEANING THE EXTERNAL UNIT We recommend cleaning the appliance with a slightly damp cloth. It should then be dried. For safety reasons, do not wash the air-condi-tioner with water.
Precautions Never clean with benzene, alcohol or solvents. Never spray with liquid insecticide or similar. CLEANING THE AIR FILTERS To maintain the air-conditioningunit at peak efficiency, we advise you to: 1.Clean the dust filter weekly.
The filters are located behind the two intake grills. The grills contain the filters. To clean the filters: 1.
Remove the intake grills by rotating them outwards. Remove the dust filter by detaching it from the external grill.
Dust filter intake grille 12 BEGIN OF SEASON CHECKS Check that the power cord and plug are undamaged and that the appliance is properly earthed. The installation instructions should be observed meticulously. END OF SEASON OPERATIONS Empty the water from the tank.
Remove the tank (9) and empty it. To drain any residual water from the internal circuit, remove the stopper (11) from the drain tube (10) and drain completely.
Re-insertthe stopper and re-positionthe tank correctly (9). Clean the anti-bacteriafilters and dry well before replacing. LIMITED WARRANTY We warrant each DE’LONGHI AIR-CONDITIONERto be free from defects in material and workmanship. Our obligation under this warranty is to provide one year parts and labor free from purchase date, with an additional four (4) years on any part of the sealed system consisting of the compressor, evaporator, condenser and factory connected refrigerant tubing. This warranty shall apply only if the AIR-CONDITIONERis used in accordance with the factory directions which accompany it, and on Alternatign Current (AC) circuit. This warranty is in lieu of all other warranties and representations, expressed or implied, and all other obligations or liabilities on our part.
We do not authorize any other person or company to assume for us any liability in connection with the sale or use of our AIR-CONDITIONER.This warranty shall not apply to assume for us any liability in connection with the sale or use of our AIR-CONDITIONER.This warranty shall not apply to any AIR-CONDITIONERwhich shall have been repaired or altered outside our factory nor shall it apply to any AIR-CONDITIONERwhich has been subjected to misuse, negligence or accidents. If repairs become necessary or spare parts are needed, please write to: De’Longhi America Inc.
De’ Longhi CANADA Park 80 West Plaza One 4th floor 1040 Ronsa Court Saddle Brook, NJ 07663 MISSISSAUGA, ONTARIO or call Service Tel. 1-800-322-3848 L4W 3Y4 CANADA.
DeLonghi CF210 Portable Air Conditioner Error code e6. DeLonghi CF210 Portable Air Conditioner. DeLonghi CF210 Portable Air Conditioner, error code e6 related issues. Get free help, solutions & advice from top DeLonghi experts. Www.fixya.com/./t4492271- error e6displayingsinglesplitmodel.
Apr 5, 2010 - Question about DeLonghi CF210 Portable Air Conditioner. Then the code error display E6 and the error code is Communication malfunction. DeLonghi fix e6 error Air Conditioners Questions & Answers. Www.fixya.com Forum Tags fix e6 error Air Conditioners. DeLonghi air conditioners fix e6 error related questions and answers. DelonghiFX400eco error code I Have the above air con unit 18 months old the cooling.
DeLonghi CF210 Portable Air Conditioner Error code e6 split Answered on Jan 13, 2019. Very likely the outside (condenser) coil is coated over with lint or leaves from the air flow of the fan blade. Generally, the obstruction cannot be seen, because it is inside the cabinet. Try this to clear the air blockage: Go inside the house and unplug the unit. Go outside and use a garden hose, with the nozzle set to a hard stream and the water supply on full.
With the nozzle held against the coil, direct the water stream straight through. Move the nozzle slowly across the entire surface of the coil several times to blow the trash off the coil to the inside of the cabinet. The unit should then continue to cool as designed. Answered on Aug 08, 2018.